Specifications, fiber grades
and the standards behind them

Typical values for each construction. Final parameters are confirmed on the quotation against your specification — if a figure here does not match your tender, tell us and we quote to yours.

GYTS / GYTA / GYTA53

Stranded Loose Tube Armoured Cable

DuctAerialDirect burial

Outside-plant cable for duct, aerial and direct-burial routes. Loose tubes stranded around a central strength member, fully water-blocked, with corrugated steel (GYTS) or aluminium tape (GYTA) armouring.

  • Fiber count2 – 288
  • Fiber typeG.652D / G.657A1 / G.655
  • ArmourPSP steel / APL aluminium
  • Operating temp.−40 °C to +70 °C
ParameterTypical value / basis
Tensile strength (short / long term)3000 N / 1000 N
Crush resistance (short / long term)3000 N/100 mm / 1000 N/100 mm
Min. bend radius (static / dynamic)10 × D / 20 × D
Sheath materialPE · LSZH on request
Standard drum length2 km / 4 km (±5 %)
Reference standardsIEC 60794-1-2, IEC 60794-3, YD/T 901

Values shown are typical for this construction and are confirmed on the quotation against your specification.

ADSS

All-Dielectric Self-Supporting Cable

AerialPower utilityNo messenger

Fully dielectric aerial cable installed along energised power lines without a messenger. Aramid strength members sized to the span and the ice and wind loading of the route.

  • Fiber count12 – 144
  • Span length50 – 1000 m
  • SheathPE or anti-tracking (AT)
  • Metal contentNone
ParameterTypical value / basis
Span / loadingEngineered per route survey
Rated tensile strengthSpecified per span and ice/wind class
Sheath selectionPE below 35 kV field · AT at or above 35 kV
Operating temperature−40 °C to +70 °C
Min. bend radius (static / dynamic)15 × D / 25 × D
Reference standardsIEC 60794-4, IEEE 1222

Values shown are typical for this construction and are confirmed on the quotation against your specification.

OPGW

Optical Ground Wire

Transmission linesEarth wireLightning

Composite overhead earth wire with an optical core, replacing the conventional shield wire on transmission lines. Stainless steel tube optical unit stranded with aluminium-clad steel wires.

  • Fiber count12 – 144
  • Optical unitStainless steel tube
  • StrandingAA / ACS wires
  • Short-circuitSpecified per line
ParameterTypical value / basis
Short-circuit current capacityEngineered to line fault level (kA²·s)
Rated tensile strengthPer tower spacing and loading class
DC resistancePer conductor configuration
Operating temperature−40 °C to +80 °C
Fiber typeG.652D (G.655 on request)
Reference standardsIEC 60794-4-10, IEEE 1138

Values shown are typical for this construction and are confirmed on the quotation against your specification.

GJXH / GJYXFCH

FTTH Bow-Type Drop Cable

FTTHIndoor/outdoorBend-insensitive

Flat bow-type drop cable for the final span into subscriber premises. All-dielectric or self-supporting with an integrated messenger, using bend-insensitive fiber for tight in-building routing.

  • Fiber count1 – 4
  • Fiber typeG.657A1 / G.657A2
  • MessengerFRP or phosphated steel
  • SheathLSZH / PVC / PE
ParameterTypical value / basis
Min. bend radius (G.657A2)7.5 mm
Tensile strength (short / long term)600 N / 300 N (self-supporting)
Crush resistance1000 N/100 mm
Flame ratingIEC 60332-1 (LSZH versions)
Standard drum length1 km / 2 km
Reference standardsYD/T 1997, IEC 60794-2

Values shown are typical for this construction and are confirmed on the quotation against your specification.

GJFJV / GJFJH / breakout

Indoor Tight-Buffered Cable

RiserPlenumData centre

Tight-buffered simplex, duplex, distribution and breakout cable for riser, plenum and equipment-room routing. Low-smoke zero-halogen sheathing for occupied buildings.

  • Fiber count1 – 24
  • Buffer900 µm tight buffer
  • SheathLSZH
  • Fiber typeG.652D / OM3 / OM4
ParameterTypical value / basis
Flame propagationIEC 60332-1-2 / IEC 60332-3-24
Smoke densityIEC 61034-2
Halogen / acid gasIEC 60754-1 / -2
Tensile strength (short / long term)660 N / 220 N (4-fiber distribution)
Min. bend radius (static / dynamic)10 × D / 20 × D
Reference standardsIEC 60794-2, ISO/IEC 11801

Values shown are typical for this construction and are confirmed on the quotation against your specification.

Patch cords · Pigtails · ODF

Connectivity & Distribution Hardware

Patch cordsMPO/MTPODF

Factory-terminated patch cords, pigtails, MPO/MTP trunks, adapter panels, splice closures and ODF frames — supplied as matched sets so the field termination and the cable plant agree.

  • ConnectorsLC / SC / FC / ST / MPO-MTP
  • PolishUPC / APC
  • Insertion loss≤ 0.3 dB (single-mode)
  • Return loss≥ 50 dB UPC · ≥ 60 dB APC
ParameterTypical value / basis
Insertion loss (single-mode, typical)≤ 0.3 dB
Return loss≥ 50 dB (UPC) · ≥ 60 dB (APC)
Durability≥ 500 mating cycles, ≤ 0.2 dB change
Operating temperature−20 °C to +70 °C
Test dataPer-connector interferometer IL/RL report
Reference standardsIEC 61754, IEC 61300-3-34, Telcordia GR-326

Values shown are typical for this construction and are confirmed on the quotation against your specification.

Reference

Fiber grades

Attenuation figures are maximum specification values to ITU-T; measured values on delivered cable are reported per fiber in the factory test report.

GradeDescriptionMax. attenuationCut-off / bandwidthTypical use
G.652DStandard single-mode≤ 0.36 dB/km @1310 · ≤ 0.22 dB/km @15501260 nmBackbone, duct, OPGW, general outside plant
G.657A1Bend-tolerant single-mode≤ 0.36 dB/km @1310 · ≤ 0.22 dB/km @15501260 nmFTTH distribution, riser, cabinet routing
G.657A2High bend tolerance≤ 0.36 dB/km @1310 · ≤ 0.22 dB/km @15501260 nmDrop cable, in-building, 7.5 mm bend radius
G.655Non-zero dispersion shifted≤ 0.22 dB/km @15501450 nmLong-haul DWDM routes
OM3Laser-optimised multimode 50/125≤ 3.0 dB/km @8502000 MHz·km @85010G to 300 m, data centre
OM4Laser-optimised multimode 50/125≤ 3.0 dB/km @8504700 MHz·km @85010G to 550 m, 40G/100G short reach

Standards

What we quote against

These are the published standards the constructions above are built and tested to. They are public documents — if your tender references a different or additional standard, send it with the enquiry and we respond against that instead.

Where a certificate belongs to the manufacturing mill rather than to us, it is supplied in the mill’s name and we say so.

StandardScope
IEC 60794-1-2Optical fibre cables — generic specification and test procedures
IEC 60794-3Outdoor cables — sectional specification
IEC 60794-4Aerial optical cables along electrical power lines
ITU-T G.652 / G.657Single-mode fibre and cable characteristics
IEEE 1138Optical ground wire (OPGW) for electrical utilities
IEEE 1222All-dielectric self-supporting (ADSS) fibre optic cable
IEC 60332 / 60754 / 61034Flame propagation, halogen and smoke performance
Telcordia GR-20-COREGeneric requirements for optical fibre and cable

Technical FAQ

Questions buyers ask before ordering

What do you need from me to quote?

Fiber count and grade, cable construction or an equivalent part number, armouring and sheath material, drum length, total quantity, destination port and required delivery window. If you have a drawing or an existing datasheet, send that instead — we quote against it directly.

GYTS or GYTA — which should I specify?

Both are stranded loose tube designs. GYTS uses corrugated steel tape armouring, GYTA aluminium tape. Steel gives better rodent and crush protection for direct burial; aluminium is lighter and non-magnetic, often preferred in duct or where induced currents matter.

When do I need an anti-tracking sheath on ADSS?

Electric field strength at the cable position drives it. As a working rule, standard PE is used below roughly 35 kV field conditions and an AT sheath at or above that. Span and loading class should come from a route survey, not a catalogue default.

Can you match a cable already in my network?

Yes. Send the printed sheath marking, the original datasheet or a sample length. Matching fiber grade, tube count and sheath dimensions matters if the new cable will be spliced into or pulled alongside existing plant.

What is the difference between G.657A1 and G.657A2?

Both are bend-tolerant single-mode and backward compatible with G.652D. A2 tolerates tighter bends — down to a 7.5 mm radius — which is why it is normally specified for drop cable and in-building routing where installers cannot control the bend.

Do you supply test data with the cable?

Yes. Every drum ships with a factory test report covering attenuation per fiber at the relevant wavelengths, plus the OTDR trace. Length, drum number and batch are recorded against the report so the documentation matches the physical drum.

What drum lengths are standard?

2 km and 4 km are the common outside-plant lengths, with ±5 % tolerance. Non-standard lengths can be wound to order — useful when your span layout would otherwise leave an awkward offcut, though it affects price and lead time.

How is the cable packed for sea freight?

Wooden or steel-reinforced drums, both cable ends sealed and accessible for pre-installation testing, drum lagged for container transit. Marking shows cable type, fiber count, length, drum number and batch.

Can you supply to a written specification or tender?

Yes — that is the preferred way to work. Send the specification and we respond clause by clause, flagging anything we cannot meet rather than quoting around it.

What are your payment and delivery terms?

Quoted per order against incoterms and destination. Terms, lead time and the applicable incoterm are stated on the quotation itself before anything is confirmed.

Have a specification ready?

Send the fiber count, construction and quantity. We respond with a written quotation, lead time and the datasheet for the exact construction quoted.