Products
Specifications, fiber grades
and the standards behind them
Typical values for each construction. Final parameters are confirmed on the quotation against your specification — if a figure here does not match your tender, tell us and we quote to yours.
Stranded Loose Tube Armoured Cable
Outside-plant cable for duct, aerial and direct-burial routes. Loose tubes stranded around a central strength member, fully water-blocked, with corrugated steel (GYTS) or aluminium tape (GYTA) armouring.
- Fiber count2 – 288
- Fiber typeG.652D / G.657A1 / G.655
- ArmourPSP steel / APL aluminium
- Operating temp.−40 °C to +70 °C
| Parameter | Typical value / basis |
|---|---|
| Tensile strength (short / long term) | 3000 N / 1000 N |
| Crush resistance (short / long term) | 3000 N/100 mm / 1000 N/100 mm |
| Min. bend radius (static / dynamic) | 10 × D / 20 × D |
| Sheath material | PE · LSZH on request |
| Standard drum length | 2 km / 4 km (±5 %) |
| Reference standards | IEC 60794-1-2, IEC 60794-3, YD/T 901 |
Values shown are typical for this construction and are confirmed on the quotation against your specification.
All-Dielectric Self-Supporting Cable
Fully dielectric aerial cable installed along energised power lines without a messenger. Aramid strength members sized to the span and the ice and wind loading of the route.
- Fiber count12 – 144
- Span length50 – 1000 m
- SheathPE or anti-tracking (AT)
- Metal contentNone
| Parameter | Typical value / basis |
|---|---|
| Span / loading | Engineered per route survey |
| Rated tensile strength | Specified per span and ice/wind class |
| Sheath selection | PE below 35 kV field · AT at or above 35 kV |
| Operating temperature | −40 °C to +70 °C |
| Min. bend radius (static / dynamic) | 15 × D / 25 × D |
| Reference standards | IEC 60794-4, IEEE 1222 |
Values shown are typical for this construction and are confirmed on the quotation against your specification.
Optical Ground Wire
Composite overhead earth wire with an optical core, replacing the conventional shield wire on transmission lines. Stainless steel tube optical unit stranded with aluminium-clad steel wires.
- Fiber count12 – 144
- Optical unitStainless steel tube
- StrandingAA / ACS wires
- Short-circuitSpecified per line
| Parameter | Typical value / basis |
|---|---|
| Short-circuit current capacity | Engineered to line fault level (kA²·s) |
| Rated tensile strength | Per tower spacing and loading class |
| DC resistance | Per conductor configuration |
| Operating temperature | −40 °C to +80 °C |
| Fiber type | G.652D (G.655 on request) |
| Reference standards | IEC 60794-4-10, IEEE 1138 |
Values shown are typical for this construction and are confirmed on the quotation against your specification.
FTTH Bow-Type Drop Cable
Flat bow-type drop cable for the final span into subscriber premises. All-dielectric or self-supporting with an integrated messenger, using bend-insensitive fiber for tight in-building routing.
- Fiber count1 – 4
- Fiber typeG.657A1 / G.657A2
- MessengerFRP or phosphated steel
- SheathLSZH / PVC / PE
| Parameter | Typical value / basis |
|---|---|
| Min. bend radius (G.657A2) | 7.5 mm |
| Tensile strength (short / long term) | 600 N / 300 N (self-supporting) |
| Crush resistance | 1000 N/100 mm |
| Flame rating | IEC 60332-1 (LSZH versions) |
| Standard drum length | 1 km / 2 km |
| Reference standards | YD/T 1997, IEC 60794-2 |
Values shown are typical for this construction and are confirmed on the quotation against your specification.
Indoor Tight-Buffered Cable
Tight-buffered simplex, duplex, distribution and breakout cable for riser, plenum and equipment-room routing. Low-smoke zero-halogen sheathing for occupied buildings.
- Fiber count1 – 24
- Buffer900 µm tight buffer
- SheathLSZH
- Fiber typeG.652D / OM3 / OM4
| Parameter | Typical value / basis |
|---|---|
| Flame propagation | IEC 60332-1-2 / IEC 60332-3-24 |
| Smoke density | IEC 61034-2 |
| Halogen / acid gas | IEC 60754-1 / -2 |
| Tensile strength (short / long term) | 660 N / 220 N (4-fiber distribution) |
| Min. bend radius (static / dynamic) | 10 × D / 20 × D |
| Reference standards | IEC 60794-2, ISO/IEC 11801 |
Values shown are typical for this construction and are confirmed on the quotation against your specification.
Connectivity & Distribution Hardware
Factory-terminated patch cords, pigtails, MPO/MTP trunks, adapter panels, splice closures and ODF frames — supplied as matched sets so the field termination and the cable plant agree.
- ConnectorsLC / SC / FC / ST / MPO-MTP
- PolishUPC / APC
- Insertion loss≤ 0.3 dB (single-mode)
- Return loss≥ 50 dB UPC · ≥ 60 dB APC
| Parameter | Typical value / basis |
|---|---|
| Insertion loss (single-mode, typical) | ≤ 0.3 dB |
| Return loss | ≥ 50 dB (UPC) · ≥ 60 dB (APC) |
| Durability | ≥ 500 mating cycles, ≤ 0.2 dB change |
| Operating temperature | −20 °C to +70 °C |
| Test data | Per-connector interferometer IL/RL report |
| Reference standards | IEC 61754, IEC 61300-3-34, Telcordia GR-326 |
Values shown are typical for this construction and are confirmed on the quotation against your specification.
Reference
Fiber grades
Attenuation figures are maximum specification values to ITU-T; measured values on delivered cable are reported per fiber in the factory test report.
| Grade | Description | Max. attenuation | Cut-off / bandwidth | Typical use |
|---|---|---|---|---|
| G.652D | Standard single-mode | ≤ 0.36 dB/km @1310 · ≤ 0.22 dB/km @1550 | 1260 nm | Backbone, duct, OPGW, general outside plant |
| G.657A1 | Bend-tolerant single-mode | ≤ 0.36 dB/km @1310 · ≤ 0.22 dB/km @1550 | 1260 nm | FTTH distribution, riser, cabinet routing |
| G.657A2 | High bend tolerance | ≤ 0.36 dB/km @1310 · ≤ 0.22 dB/km @1550 | 1260 nm | Drop cable, in-building, 7.5 mm bend radius |
| G.655 | Non-zero dispersion shifted | ≤ 0.22 dB/km @1550 | 1450 nm | Long-haul DWDM routes |
| OM3 | Laser-optimised multimode 50/125 | ≤ 3.0 dB/km @850 | 2000 MHz·km @850 | 10G to 300 m, data centre |
| OM4 | Laser-optimised multimode 50/125 | ≤ 3.0 dB/km @850 | 4700 MHz·km @850 | 10G to 550 m, 40G/100G short reach |
Standards
What we quote against
These are the published standards the constructions above are built and tested to. They are public documents — if your tender references a different or additional standard, send it with the enquiry and we respond against that instead.
Where a certificate belongs to the manufacturing mill rather than to us, it is supplied in the mill’s name and we say so.
| Standard | Scope |
|---|---|
| IEC 60794-1-2 | Optical fibre cables — generic specification and test procedures |
| IEC 60794-3 | Outdoor cables — sectional specification |
| IEC 60794-4 | Aerial optical cables along electrical power lines |
| ITU-T G.652 / G.657 | Single-mode fibre and cable characteristics |
| IEEE 1138 | Optical ground wire (OPGW) for electrical utilities |
| IEEE 1222 | All-dielectric self-supporting (ADSS) fibre optic cable |
| IEC 60332 / 60754 / 61034 | Flame propagation, halogen and smoke performance |
| Telcordia GR-20-CORE | Generic requirements for optical fibre and cable |
Technical FAQ
Questions buyers ask before ordering
What do you need from me to quote?
Fiber count and grade, cable construction or an equivalent part number, armouring and sheath material, drum length, total quantity, destination port and required delivery window. If you have a drawing or an existing datasheet, send that instead — we quote against it directly.
GYTS or GYTA — which should I specify?
Both are stranded loose tube designs. GYTS uses corrugated steel tape armouring, GYTA aluminium tape. Steel gives better rodent and crush protection for direct burial; aluminium is lighter and non-magnetic, often preferred in duct or where induced currents matter.
When do I need an anti-tracking sheath on ADSS?
Electric field strength at the cable position drives it. As a working rule, standard PE is used below roughly 35 kV field conditions and an AT sheath at or above that. Span and loading class should come from a route survey, not a catalogue default.
Can you match a cable already in my network?
Yes. Send the printed sheath marking, the original datasheet or a sample length. Matching fiber grade, tube count and sheath dimensions matters if the new cable will be spliced into or pulled alongside existing plant.
What is the difference between G.657A1 and G.657A2?
Both are bend-tolerant single-mode and backward compatible with G.652D. A2 tolerates tighter bends — down to a 7.5 mm radius — which is why it is normally specified for drop cable and in-building routing where installers cannot control the bend.
Do you supply test data with the cable?
Yes. Every drum ships with a factory test report covering attenuation per fiber at the relevant wavelengths, plus the OTDR trace. Length, drum number and batch are recorded against the report so the documentation matches the physical drum.
What drum lengths are standard?
2 km and 4 km are the common outside-plant lengths, with ±5 % tolerance. Non-standard lengths can be wound to order — useful when your span layout would otherwise leave an awkward offcut, though it affects price and lead time.
How is the cable packed for sea freight?
Wooden or steel-reinforced drums, both cable ends sealed and accessible for pre-installation testing, drum lagged for container transit. Marking shows cable type, fiber count, length, drum number and batch.
Can you supply to a written specification or tender?
Yes — that is the preferred way to work. Send the specification and we respond clause by clause, flagging anything we cannot meet rather than quoting around it.
What are your payment and delivery terms?
Quoted per order against incoterms and destination. Terms, lead time and the applicable incoterm are stated on the quotation itself before anything is confirmed.